• P D Gupta

      Articles written in Sadhana

    • A second-order autocorrelator for single-shot measurement of femtosecond laser pulse durations

      M Raghuramaiah A K Sharma P A Naik P D Gupta R A Ganeev

      More Details Abstract Fulltext PDF

      A second-order autocorrelator for single-shot measurement of ultrashort laser pulse durations has been set up. It is based on recording the spatial profile of non-collinear phase-matched second harmonic generation in a KDP crystal using a CCD camera-framegrabber combination. Performance of the system is described from measurement of 250 femtosecond transform-limited laser pulses from a passively mode-locked, diode pumped Nd:glass laser. It can also be used for measurement of picosecond laser pulses in the multi-shot scanning mode.

    • Control and analysis software for a laser scanning microdensitometer

      H R Bundel C P Navathe P A Naik P D Gupta

      More Details Abstract Fulltext PDF

      A PC-based control software and data acquisition system is developed for an existing commercial microdensitometer (Biomed make model No. SL-2D/1D UV/VIS) to facilitate scanning and analysis of X-ray films. The software is developed in Labview, which includes operation of the microdensitometer in 1D and 2D scans and analysis of spatial or spectral data on X-ray films, such as optical density, intensity and wavelength. It provides a user-friendly Graphical User Interface (GUI) to analyse the scanned data and also store the analysed data/image in popular formats like data in Excel and images in jpeg. It has also on-line calibration facility with standard optical density tablets. The control software and data acquisition system is simple, inexpensive and versatile.

    • Development of single frame X-ray framing camera for pulsed plasma experiments

      J Upadhyay J A Chakera C P Navathe P A Naik A S Joshi P D Gupta

      More Details Abstract Fulltext PDF

      A single-frame X-ray framing camera has been set up for fast imaging of X-ray emissions from pulsed plasma sources. It consists of two parts, viz. an X-ray pin-hole camera using an open-ended microchannel plate (MCP) detector coupled to a CCD camera, and a high voltage short duration gate pulse for the MCP. The camera uses a 10-Μm pin-hole aperture for imaging on the MCP detector with a magnification of 6 X. The high voltage pulser circuit generates a pulse of variable duration from 5 to 30 ns (at 70% of peak amplitude) with variable amplitude from 800 V to 1.25 kV, and is triggered through a laser pulse synchronized with the event to be recorded. The performance of the system has been checked by recording X-ray emission from a laser-produced copper plasma. A reduction factor of ∼ 6.5 is seen in the dark current contribution as the MCP gate pulse is decreased from 250Μs to 5 ns duration.

    • Design and performance characteristics of an electromagnetic interference shielded enclosure for high voltage Pockels cell switching system

      A K Sharma K K Mishra M Raghuramaiah P A Naik P D Gupta

      More Details Abstract Fulltext PDF

      An electro-magnetic interference noise shielding enclosure for Pockels cells for high speed synchronized switching has been set-up and tested. The shielding effectiveness of the aluminum enclosures housing the Pockels cells and the electronic circuitry has been measured using a high impedance probe and is found to be $\sim 50 dB$. This ensures a noise-free and synchronized electro-optic switching in an Nd:glass re-generative amplifier of chirped pulse amplification based table top terawatt laser system.

    • Design, development and performance characteristics of a large aperture disc amplifier for high power Nd: Glass laser chain

      M P Kamath P K Tripathi A P Kulkarni R Chandra A S Joshi C P Navathe P D Gupta

      More Details Abstract Fulltext PDF

      A large aperture disc amplifier has been designed, set-up and characterized for its performance on small signal gain, spatial variation of gain, and thermal recovery time. This amplifier, consisting of three elliptical Nd: phosphate glass discs of size 214 × 114 × 20 mm mounted at Brewster angle and pumped by ten xenon filled flash lamps of 600 mm arc length, provided a small signal gain of 6 at electrical pump energy of 36 kJ (in a pulse of 450 𝜇s) using an in-house developed dual-polarity capacitor bank based power supply. It was coupled to a high power Nd: phosphate glass laser chain and a maximum output pulse energy exceeding 100 J in a 1·5 ns (FWHM) pulse has been measured. A dry nitrogen gas based cooling system was developed for cooling the glass discs with a thermal recovery time of ∼ 20 minutes.

    • Generation of intense soft X-rays from capillary discharge plasmas

      Y B S R Prasad S Nigam K Aneesh S Barnwal P K Tripathi P A Naik C P Navathe P D Gupta

      More Details Abstract Fulltext PDF

      X-ray lasing through high voltage, high current discharges in gas filled capillaries has been demonstrated in several laboratories. This method gives highest number of X-ray photons per pulse. The fast varying current and the j x B magnetic force compress the plasma towards the axis forming a hot, dense, line plasma, wherein under appropriate discharge conditions lasing occurs. At Laser Plasma Division, RRCAT, a program on high voltage capillary discharge had been started. The system consists of a 400 kV Marx bank, water line capacitor, spark gap and capillary chamber. The initial results of the emission of intense short soft X-ray pulses (5–10 ns) from the capillary discharge are reported.