Volume 77 Issue 4 October 2011 pp 749-757 Research Articles
Inhalation of radon has been recognized as a health hazard. In the present work radon concentration was measured, in the atmosphere of the archaeological place, namely Catacomb of Kom El-Shuqafa, in Alexandria, Egypt, which is open to the public, using time-integrated passiveradon dosimeters containing LR-115 solid-state nuclear track detector. The measurements were performed throughout winter and summer. Seasonal variation of radon concentration, with the maximum in summer ranging from 243 to 574 Bq m-3 and minimum in winter ranging from 64 to 255 Bq m-3 was observed. Because of the variations of the catacomb ventilation system, the equilibrium factor between radon and its progeny ranges from 0.14 to 0.48. The tour guides are exposed to an average estimated annual effective dose ranging from 0.21 to 0.52 mSv y-1 and the visitors from 0.88 to 2.28 𝜇Sv y-1. The effective doses the catacomb workers are exposed to ranged from 0.20 mSv y-1 in winter to 4.65 mSv y-1 in summer which exceeds the lower bound of the recommended level (3–10 mSv y-1) (ICRP, 1993).
Volume 96, 2022
All articles
Continuous Article Publishing mode
Click here for Editorial Note on CAP Mode
© 2021-2022 Indian Academy of Sciences, Bengaluru.