KUMAR SURESH
Articles written in Pramana – Journal of Physics
Volume 86 Issue 6 June 2016 pp 1269-1274 Regular
PRAJAPATI P M PANDEY BHAWNA GUPTA N C KUMAR SURESH NAYAK B K SAXENA A SURYANARAYANA S V JAKHAR S VALA SUDHIRSINH RAO C V S BASU T K
Measurement of double-differential cross-sections of 14 MeV neutron-inducedcharged-particle productions is very important for estimating the nuclear heating and radiation damage of a fusion reactor. Only a few experimental data are available even though the nuclear reaction cross-section data of structural materials are important in fusion nuclear technology. In this context,general purpose scattering chamber facility has been developed for accelerator-based 14 MeV DT neutron generator to measure double-differential nuclear reaction cross-section at Fusion Neutronics Laboratory, IPR. It has been designed for experiments using silicon surface barrier detectors forthe online detection of charged particles. It offers flexibility in the arrangement of silicon surface barrier detectors.
Volume 97, 2023
All articles
Continuous Article Publishing mode
Click here for Editorial Note on CAP Mode