• Comparative analytical and experimental study of fabricated identical surface and interior permanent magnet BLDC motor prototypes

    • Fulltext

       

        Click here to view fulltext PDF


      Permanent link:
      https://www.ias.ac.in/article/fulltext/sadh/045/0026

    • Keywords

       

      BLDC motors; surface-mounted PM; interior PM; induced emf; air-gap flux density; inductance; fault tolerance; torque ripple; torque–speed characteristics; FEM analysis; fabrication; comparative study.

    • Abstract

       

      This paper presents a novel and exhaustive investigation involving in-depth analysis, performance evaluation and comparative study of two 0.75 hp, 4-pole, 1500 rpm laboratory prototypes of Brushless DC (BLDC) motors of identical nominal ratings with surface and interior permanent magnet rotor structures havingthe same stator and winding (integral slot distributed winding). Both the motors were designed and developed in the lab. The major electrical variables (such as rated power, speed, voltage, current, number of poles, etc.) and the stator (such as core material, stator lamination, stack length, winding pattern and wire gauge) of the fabricated prototypes have also been kept identical to pin-point the direct influence of the two different rotor configurations (viz., surface vs interior permanent magnet) on the parameters, performance and operation ofthese BLDC motors. Additionally, to ensure unbiased basis for appropriate comparison, the overall volumes of magnets/pole in both the motors have also been kept similar. A detailed comparison of different quantities likeair-gap flux density distribution, THD in induced voltage, torque ripple, losses and efficiency, torque–speed characteristics with field-weakening capability, steady state parameters at different operating conditions, etc. has been conducted for the said motors and the salient points duly highlighted. The vulnerability of the permanent magnets to demagnetisation based on armature reaction, particularly during a sudden fault, has also been investigated in both the cases. The theoretically determined parameters and analytically evaluated performancefigures have been verified through standard FEM packages, and later validated experimentally on the fabricated prototypes. Very good mutual agreement has been observed between predicted and experimental values.

    • Author Affiliations

       

      PINAKI MUKHERJEE1 SOURABH PAITANDI1 MAINAK SENGUPTA1

      1. Department of Electrical Engineering, Indian Institute of Engineering Science and Technology, Shibpur 711103, India
    • Dates

       
  • Sadhana | News

    • Editorial Note on Continuous Article Publication

      Posted on July 25, 2019

      Click here for Editorial Note on CAP Mode

© 2021-2022 Indian Academy of Sciences, Bengaluru.