• Computational study on effects of rib height and thickness on heat transfer enhancement in a rib roughened square channel

    • Fulltext

       

        Click here to view fulltext PDF


      Permanent link:
      https://www.ias.ac.in/article/fulltext/sadh/041/06/0667-0678

    • Keywords

       

      Heat transfer enhancement; turbulent flow; ribbed channel; broken ribs; CFD

    • Abstract

       

      A computational study was carried out for the heat transfer augmentation in a three-dimensional square channel fitted with different types of ribs. The standard k–e model and its two variants (RNG and realizable) were used for turbulence modeling. The predictions were compared with available experimental andcomputational results. Three rib configurations were used in the present study: 90° continuous attached ribs, 60° V-shaped broken attached thick and thin ribs. It was observed that the maximum heat transfer occurs at the normalized rib spacing (p/e) = 10 in the case of 90° attached ribs. The effects of the blockage ratio and rib thickness were investigated for 60° V-shaped broken ribs with Re = 10,000–30,000 and p/e = 10. It was observed that the average Nusselt number decreases with an increase in the Reynolds number for almost all configurations studied in the present study. For the 60° V-shaped broken ribs, increasing the blockage ratio had an adverse effect on the heat transfer. It was also observed that thin ribs perform better than thick ribs.

    • Author Affiliations

       

      ANUJ K SHUKLA ANUPAM DEWAN1

      1. Department of Applied Mechanics, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
    • Dates

       
  • Sadhana | News

    • Editorial Note on Continuous Article Publication

      Posted on July 25, 2019

      Click here for Editorial Note on CAP Mode

© 2017-2019 Indian Academy of Sciences, Bengaluru.