      Ac-dc conversion; controlled rectification; power factor correction; PWM converter; synchronous reference frame control; vector control.

    • Abstract

       

      A vector control scheme is presented for a three-phase AC/DC converter with bi-directional power flow capability. A design procedure for selection of control parameters is discussed. A simple algorithm for unit-vector generation is presented. Starting current transients are studied with particular emphasis on high-power applications, where the line-side inductance is low. A starting procedure is presented to limit the transients. Simulation and experimental results are also presented.

    • Author Affiliations

       

      J S Siva Prasad1 Tushar Bhavsar1 Rajesh Ghosh1 G Narayanan1

      1. Department of Electrical Engineering, Indian Institute of Science, Bangalore 560 012