      Interior permanent magnet synchronous motor; direct torque control; stator flux linkage; active power filter; voltage harmonics; torque ripples

    • Abstract

       

      This paper describes an active filter topology to improve the performance of hysteresis direct torque control (HDTC) of interior permanent magnet synchronous motor (IPMSM). The filter topology consists of an active filter and two RLC filters, and is connected to the main power circuit through a 1:1 transformer. The active filter is characterized by detecting the harmonics in the motor phase voltages and injecting equivalent harmonic voltages to produce almost sinusoidal voltage waveform to the motor terminals. The active filter uses hysteresis voltage controller while the motor main circuit uses hysteresis direct torque control. The simulation results of this combined control structure show considerable torque ripple reduction in the steady state range and adequate dynamic torque performance as well as considerable harmonic voltage and EMI noise reduction.

    • Author Affiliations

       

      Kayhan Gulez1 Ali Ahmed Adam1 Halit Pastaci1

      1. Electrical-Electronic Faculty, Electrical Engineering Department, Yildiz Technical University, Besiktas-Istanbul - 34349, Turkey