    • Abstract

       

      This paper presents the design and performance analysis of an indigenously developed 110 W average output power copper HyBrID laser operating at 16 kHz pulse repetition rate. The laser active medium was confined within a fused silica tube of $\sim 6$ cm diameter and $\sim 200$ cm active length. An in-house developed high-power ($\sim 10$ kW) solid-state pulser was used as the electrical excitation source. A simple estimation of deposited electrical power, at the laser head, was carried out and based on it, the laser tube efficiency was found to be 2.9% at 70 W and 2.2% at 110 W laser power levels.

    • Author Affiliations

       

      R Biswal1 P K Agrawal1 G K Mishra1 S V Nakhe1 S K Dixit1 J K Mittal1

      1. Laser Systems Engineering Division, Raja Ramanna Centre for Advanced Technology, Indore 452 013, India