• Fulltext

       

        Click here to view fulltext PDF


      Permanent link:
      https://www.ias.ac.in/article/fulltext/pram/057/01/0135-0139

    • Keywords

       

      Data acquisition; multi-detector arrays; CAMAC

    • Abstract

       

      Experiments with multi-detector arrays have special requirements and place higher demands on computer data acquisition systems. In this contribution we discuss data acquisition systems with special emphasis on multi-detector arrays and in particular we describe a new data acquisition system, AMPS which we have developed recently which is in regular use in experiments at the Pelletron Laboratory, Mumbai. This includes the in-house development of a dedicated crate controller, PC interface card and software.

    • Author Affiliations

       

      A Chatterjee1 Sushil Kamerkar1 A K Jethra1 S Padmini1 M P Diwakar1 S S Pande1 M D Ghodgaonkar1

      1. Nuclear Physics Division and Electronics Division, Bhabha Atomic Research Centre, Trombay, Mumbai - 400 085, India
    • Dates

       
  • Pramana – Journal of Physics | News

    • Editorial Note on Continuous Article Publication

      Posted on July 25, 2019

      Click here for Editorial Note on CAP Mode

© 2017-2019 Indian Academy of Sciences, Bengaluru.