Solid state effects during deuterium implantation into copper and titanium
H K Sahu M C Valsakumar B Panigrahi K G M Nair K Krishan
Click here to view fulltext PDF
Permanent link:
https://www.ias.ac.in/article/fulltext/pram/039/02/0117-0130
Results of neutron counting experiments during deuterium implantation into titanium and copper are reported. Models for neutron yield have been developed by taking into account different solid state effects like energy degradation of incident ions, energy dependent d-d fusion cross section and diffusion of implanted deuterium possibly influenced by surface desorption and formation of metal deuterides. The asymptotic time dependence of the neutron yield during implantation has been compared with the experimental results. Using these results, solid state processes that might occur during deuterium implantation into these metals are inferred.
H K Sahu1 M C Valsakumar1 B Panigrahi1 K G M Nair1 K Krishan1
Volume 97, 2023
All articles
Continuous Article Publishing mode
Click here for Editorial Note on CAP Mode