      Picosecond half-lives; nuclear excited states; plunger set-up; flat and uniform target and stopper foils; capacitance measurement

    • Abstract

       

      A plunger set-up has been designed and constructed to measure picosecond nuclear half-lives using recoil distance method (RDM). The system has been used to measure the half-lives of nuclear states in35Cl,37,38Ar and40K. The shortest half-life measured with the system isT1/2=0.36(14) ps for the 4366 keV (8+) state and the longest half-life isT1/2=1.10(7) ns for the 2543 keV (7+) state in40K.

    • Author Affiliations

       

      H C Jain1 S Chattopadhyay1 Y K Agarwal1 M L Jhingan1 S K Mitra1 H V Panchal1 A Roy1 2

      1. Tata Institute of Fundamental Research, Bombay - 400 005, India
      2. Nuclear Science Center, JNU Campus, New Delhi - 110 067, India