• Track recording properties of soda glass detector for accelerated heavy ions

    • Fulltext

       

        Click here to view fulltext PDF


      Permanent link:
      https://www.ias.ac.in/article/fulltext/pram/025/01/0029-0041

    • Keywords

       

      Glass detector; energy resolution; critical angle; response curve; etching efficiency; diameter distribution; annealing

    • Abstract

       

      The etch pit diameters of soda glass detector samples exposed to54132Xe-ions of different energies are measured for different etching times after etching the detector in a ‘new etchant’ free of the adverse effect of the etch product layer. The dependence of track diameter on the energy and on the energy loss, dE/dx of54132Xe-ion in soda glass has been presented. The energy resolution of soda glass and the critical angle for etching of fission fragment tracks in glass detectors have also been determined. The maximum etched track length of54132Xe-ion in soda glass has been compared with the theoretical range. The effects of different annealing conditions on bulk etch rate of glass detector and on diameters of54132Xe-ion tracks have been presented. Experimental results show that there is a decrease in track etch rate, etching efficiency and etchable range of54132Xe-ions with annealing. The annealing of oblique tracks shows that the vertical tracks are more stable than the oblique tracks.

    • Author Affiliations

       

      S M Farid1

      1. Department of Physics, Rajshahi University, Rajshahi, Bangladesh
    • Dates

       
  • Pramana – Journal of Physics | News

    • Editorial Note on Continuous Article Publication

      Posted on July 25, 2019

      Click here for Editorial Note on CAP Mode

© 2017-2019 Indian Academy of Sciences, Bengaluru.