| Vol. 53,
No. 3 September 1999 pp. 535-539 Measurement of the ground state 2 n pickup probability for 28 Si + 68Zn and its role in sub-barrier fusion enhancement VANDANA TRIPATHI 1 ,LAGY T BABY 1 , P V MADHUSUDHANA RAO 2 ,S K HUI 3 , R SINGH 4 , J J DAS 1 , P SUGATHAN 1 ,N MADHAVAN 1 and A K SINHA 1 1Nuclear Science Centre, P.B. No.
10502, New Delhi 110 067, India Abstract. The ground state and excited state transfer yields for the 2-neutron pickup channel in the 28 Si + 68 Zn system have been measured explicitly. The recoil mass separator at the Nuclear Science Centre, New Delhi was used for the measurement. A NaI(Tl) detector was used for detecting the de-excitation g 's from the transfer products. The kinematic coincidence technique was employed for the transfer measurement. Simplified coupled channels calculations show that out of all transfer channels the major contribution to the sub-barrier enhancement comes from the ground state 2 neutron pickup channel with a ground state Q-value of + 1.83 MeV. Keywords. Heavy-ion fusion; sub-barrier enhancement; ground state transfer; kinematic coinci-dence; simplified coupled channel calculation. PACS Nos 25.70.Hi; 25.70.Jj |